Size | 5.0mm & 4.0mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Brand | Sharma |
No. Of Hole | 3,4,5,6,7,8,9,10,11,12 |
Distance Between Hole | 18.0mm |
Profile | 20.0mm/13.5mm X 4.0mm |
Suitable For | Osteotomy Of Distal Tibia |
Proximal Screw | Cortex Locked Screw (5.0mm) |
Screw Length | 20.0mm To 64.0mm (diff. 2.0mm), 10.0mm To 60.0mm (diff. 2.0mm) |
Distal Screw | Cancellous Locked Screw (4.0mm) |
View Complete details
Size | 5.0mm & 6.5mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Brand | Sharma |
No. Of Hole | 3,4,5,6,7,8,9,10,11,12,13 |
Distance Between Hole | 18.0mm |
Profile | 45.0mm / 16.0mm X 6.0mm |
Suitable For | Distal Shaft Fractures Of Femur |
Proximal Screw | Cortex Locked Screw 5.0mm |
Distal Screw | Cancellous Locked Screw (5.0mm), Cancellous Locked Screw (6.5mm) |
Screw Length | 20.0mm To 64.0mm (diff. 2.0mm), 20.0mm To 100.0mm (diff. 5.0mm) |
View Complete details
Size | 5.0mm & 6.5mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Brand | Sharma |
No. Of Hole | 4,5,6,7,8,9,10,11,12 |
Distance Between Hole | 18.0mm |
Profile | 17.5mm & 6.0mm |
Suitable For | Trochanteric Fracture Of Femur |
Proximal Screw | Cancellous Locked Screw (6.5mm) |
Screw Length | 20.0mm To 100.0mm (diff. 5.0mm), 20.0mm To 64.0mm (diff. 2.0mm) |
Distal Screw | Cortex Locked Screw (5.0mm) |
View Complete details
Size | 6.0mm x 6.5mm(Screw) |
Brand | Sharma |
Material | Stainless steel 316l / 316lvm / Titanium |
No. Of Hole | 4,5,6,7,8,9,10,11,12 |
Profile | 16.0mm x 6.0mm |
Suitable For | Supracondylar fracture distal femur fracture |
Screw Type | Cortex locked screw (5.0mm),Cancellous locked screw (6.5mm) |
Screw Length | 20.0mm to 64.0mm (diff. 2.0mm),20.0mm to 100.0mm (diff. 5.0mm) |
View Complete details
Size | 4.0mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Brand | Sharma |
No. Of Hole | 4,5,6,7,8,9,10,11,12 |
Distance Between Hole | 12.0mm |
Profile | 11.5mm X 4.0mm |
Suitable For | Proximal/medial Tibia Fractures |
Proximal Screw | Cancellous Locked Screw (4.0mm) |
Screw Length | 10.0mm To 60.0mm (diff. 2.0mm), 10.0mm To 40.0mm (diff. 2.0mm) |
Distal Screw | Cortex Locked Screw (4.0mm) |
View Complete details
Size | 4.0mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Brand | Sharma |
No. Of Hole | 4,5,6,7,8,9,10,11,12 |
Distance Between Hole | 12.0mm |
Profile | 11.5mm X 4.0mm |
Suitable For | Proximal/medial Tibia Fractures |
Proximal Screw | Cancellous Locked Screw (4.0mm) |
Screw Length | 10.0mm To 60.0mm (diff. 2.0mm), 10.0mm To 40.0mm (diff. 2.0mm) |
Distal Screw | Cortex Locked Screw (4.0mm) |
View Complete details
Material | Stainless Steel 316l / 316lvm / Titanium |
Size | 5.0mm & 6.5mm(Screw) |
Brand | Sharma |
No. Of Hole | 4,5,6,7,8,9,10,11,12,13,14,15 |
Distance Between Hole | 18.0mm |
Profile | 17.5mm & 6.0mm |
Suitable For | Trochanteric Fracture Associator With Fracture Of The Greater Trochanteric |
Proximal Screw | Cancellous Locked Screw (6.5mm) |
Screw Length | 20.0mm To 100.0mm (diff. 5.0mm), 20.0mm To 64.0mm (diff. 2.0mm) |
Distal Screw | Cortex Locked Screw (5.0mm) |
View Complete details
Material | Stainless Steel 316l / 316lvm / Titanium |
Size | 4.0mm & 3.0mm(Screw) |
Brand | Sharma |
No. Of Hole | 2,3,4,5,6,7,8,9,10,11,12 |
Distance Between Hole | 9.0mm X 13.0mm |
Profile | 106mm/10.0mm X 4.0mm |
Suitable For | Distal Tibia Fracture |
Proximal Screw | Cancellous Locked Screw (4.0mm) |
Distal Screw | Cortex Locked Screw (3.0mm) |
Screw Length | 10.0mm To 40.0mm (diff. 2.0mm), 12.0mm To 32.0mm (diff. 2.0mm) |
View Complete details
Size | 4.0mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Brand | Sharma |
No. Of Hole | 2,3,4,5,6,7,8,9,10,11,12,13,14,15 |
Distance Between Hole | 12.0mm |
Profile | 4.0mm X 12.0mm |
Suitable For | Proximal Lateral Tibia Fracture |
Proximal Screw | Cancellous Locked Screw (4.0mm) |
Screw Length | : 10.0mm To 60.0mm (diff. 2.0mm), 10.0mm To 40.0mm (diff. 2.0mm) |
Distal Screw | Cortex Locked Screw (4.0mm) |
View Complete details
Size | 4.0mm & 3.0mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Brand | Sharma |
Distance Between Hole | 13.0mm |
Profile | 38.0mm/13.0mm X 4.0mm |
Suitable For | Distal Tibia Fracture |
Proximal Screw | Cortex Locked Screw (4.0mm) |
Screw Length | 10.0mm To 40.0mm (diff. 2.0mm), 12.0mm To 32.0mm (diff. 2.0mm) |
Distal Screw | Cortex Locked Screw (3.0mm) |
View Complete details
Size | 4.0mm & 3.0mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Brand | Sharma |
No. Of Hole | 3,4,5,6,7,8,9,10,11,12 |
Distance Between Hole | 12.0mm |
Profile | 11.5mm X 3.0mm |
Suitable For | Distal Fibula Fracture |
Proximal Screw | Cortex Locked Screw( 4.0mm) |
Distal Screw | Cortex Locked Screw( 3.0mm) |
Screw Length | 10.0mm To 40.0mm (diff. 2.0mm), 12.0mm To 32.0mm (diff. 2.0mm) |
View Complete details
Size | 4.0mm & 3.0mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Brand | Sharma |
No. Of Hole | 3,4,5,6,7,8,9,10,11,12 |
Suitable For | Distal Fibula Fracture |
Proximal Screw | Cortex Locked Screw (4.0mm) |
Screw Length | 10.0mm To 40.0mm (diff. 2.0mm), 12.0mm To 32.0mm (diff. 2.0mm) |
Distal Screw | Cortex Locked Screw (3.0mm) |
View Complete details
Minimum Order Quantity: 10 Piece
Model Name/Number | SP05.CLPSS |
Size | SMALL MEDIUM LARGE |
Thickness | 3.5mm |
Material | Stainless Steel 316L / 316LVM and Titanium |
Type | Anatomical |
Usage/Application | CALCANEOUS FRACTURES |
Brand | SHARMA |
Country of Origin | Made in India |
Additional Information:
View Complete details
Size | 12.5mm, 6.5mm & 5.0mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Brand | Sharma |
No. Of Hole | 2,3,4,5,6,7,8,9,10,11,12 |
Distance Between Hole | 18.0mm |
Profile | 19.0mm X 6.0mm |
Suitable For | Trochanteric Fracture, Associated With The Greater Trochanteric Fracture |
Angle | 130 Degree, 135 Degree |
Screw Type | Lag Screw (12.5mm), Cortex Locked Screw (5.0mm), Cancellous Locked Screw (6.5mm) |
Screw Length | 25.0mm To 120.0mm (diff. 5.0mm), 10.0mm To 54.0mm (diff. 2.0mm), 20.0mm To 120.0mm (diff. 5.0mm) |
View Complete details
Material | Stainless Steel 316l, 316lvm, Titanium |
Size | 5.0mm(Screw) |
Brand | Sharma |
Screw Length | 20.0mm To 64.0mm (diff. 2.0mm) |
Shaft Part | Cortex Locked Screw 5.0mm |
Profile | 17.5mmx5.0mm |
No. Of Hole | 3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18 |
Distance Between Hole | 18.0mm |
Suitable For | Shaft Fracture Of Femur & Tibia |
View Complete details
Material | Stainless Steel 316l / 316lvm / Titanium |
Size | 6.5mm & 5.0mm(Screw) |
Brand | Sharma |
No. Of Hole | 2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18 |
Distance Between Hole | 18.0mm |
Profile | 36.0mm/16.0mm X 4.0mm |
Suitable For | Proximal Lateral Tibia Fractures |
Proximal Screw | Cancellous Locked Screw (6.5mm) |
Distal Screw | Cortex Locked Screw (5.0mm) |
Screw Length | 20.0mm To 100.0mm (diff. 5.0mm), 20.0mm To 64.0mm (diff. 2.0mm) |
View Complete details
Size | 5.0mm(Screw) |
Material | Stainless steel 316l / 316lvm / Titanium |
Brand | Sharma |
Angle | 125 Degree, 130 Degree, 135 Degree, 140 Degree |
No. Of Hole | 4,5,6,7,8,9,10,11,12 |
Distance Between Hole | 18.0mm |
Profile | 19.0mm x 6.0mm |
Suitable For | Trochanteric fracture of femur |
Screw Type | Cortex locked screw 5.0mm |
Screw Length | 20.0mm to 64.0mm (diff. 2.0mm) |
View Complete details
Size | 5.0mm(Screw) |
Material | Stainless Steel 316l,316lvm,Titanium |
Brand | Sharma |
Screw Length | 20.0mm To 64.0mm (diff. 2.0mm) |
Shaft Part | Cortex Locked Screw (5.0mm) |
No. Of Hole | 3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18 |
Distance Between Hole | 18.0mm |
Profile | 13.5mmx5.0mm |
Suitable For | Shaft Fracture Of Humerus & Tibia |
View Complete details
Size | 5.0mm (Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
No. Of Hole | 2,3,4,5,6,7,8,9,10,11,12 |
Profile | 37.0mm/17.0mm X 3.0mm |
Sterilization | 16.0mm |
Suitable For | Proximal Tibia Fractures |
Brand | Sharma |
Proximal Screw | Cancellous Locked Screw (5.0mm) |
Screw Length | 20.0mm To 64.0mm (diff. 2.0mm) |
Distal Screw | Cortex Locked Screw (5.0mm) |
View Complete details
Size | 5.0mm (Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
No. Of Hole | 2,3,4,5,6,7,8,9,10,11,12 |
Profile | 37.0mm/17.0mm X 3.0mm |
Suitable For | Proximal Tibia Fractures |
BRAND | Sharma |
View Complete details
Size | 5. 0mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Brand | Sharma |
Suitable For | Proximal Tibia Fractures |
No. Of Hole | 2,3,4,5,6,7,8,9,10,11,12 |
Distance Between Hole | 16. 0mm |
Profile | 34mm/16. 0mm X 3. 0mm |
Proximal Screw | Cancellous Locked Screw (5. 0mm) |
Screw Length | 20. 0mm To 64. 0mm (diff. 2. 0mm) |
Distal Screw | Cortex Locked Screw (5. 0mm) |
View Complete details
Material | Stainless Steel 316l / 316lvm / Titanium |
Size | 5.0mm(Screw) |
Brand | Sharma |
Suitable For | Proximal Tibia Fractures |
No. Of Hole | 2,3,4,5,6,7,8,9,10,11,12 |
Distance Between Hole | 16.0mm |
Profile | 36mm/16.0mm X 3.0mm |
Proximal Screw | Cancellous Locked Screw (5.0mm) |
Screw Length | 20.0mm To 64.0mm (diff. 2.0mm) |
Distal Screw | Cortex Locked Screw (5.0mm) |
View Complete details
Size | 4.0mm & 5.0mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Brand | Sharma |
Shape | Cloverleaf |
Screw Length | 10.0mm To 60.0mm (diff. 2.0mm), 20.0mm To 64.0mm (diff. 2.0mm) |
No. Of Hole | 2,3,4,5,6,7,8,9,10,11,12 |
Distance Between Hole | 16.0mm |
Profile | 38.5mm / 16.5mm X 3.0mm |
Suitable For | Proximal Tibia Fractures |
Proximal / Distal Screw | Cancellous Locked Screw (4.0mm), Cortex Locked Screw (5.0mm) |
View Complete details
Size | 5.0mm & 6.5mm(Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Screw Length | 20.0mm To 64.0mm (diff. 2.0mm), 20.0mm To 100.0mm (diff. 5.0mm) |
No. Of Hole | 4,5,6,7,8,9,10,11,12,13,14,15,16,17,18 |
Distance Between Hole | 18.0mm |
Profile | 50.0mm/16.0mm X 6.0mm |
Suitable For | Distal Shaft Fracture Of Femur |
Brand | Sharma |
Proximal Screw | Cortex Locked Screw (5.0mm) |
Distal Screw | Cancellous Locked Screw (6.5mm) |
View Complete details
Size | 4.5mm (Screw) |
Material | Stainless Steel 316l / 316lvm / Titanium |
Color | Black |
Packaging | Box |
Number Of Holes | 3,4,5,6,7,8,9,10,11,12,13,14 |
Distance Between Hole | 16.0mm |
Profile | 13.0mm X 1.5mm |
Suitable For | Fracture Of Radius / Ulna Fibula Use As A Tension Bone Plate On Radius / Ulna, Humerus & Tibia Plate |
Make | Sharma |
Screw Length | 10.0mm To 54.0mm (diff. 2.0mm) |
View Complete details