Call 08048114436 60% Response Rate

our range

Large Fragment Bone Plates

Large Fragment - Standard Implants and Instruments are used to fix fractures of various long bones, such as Femur and Tibia. These are also used in fixation of Peri-prosthetic fractures, Osteopenic bone and fixation of Non-unions or Malunions in adult patients.

Large Fragment System comprises Safety Locking and Standard implants and instruments.The Plates are classified according to their functions.
  • Large Fragment Spoon Plate
  • Large Fragment Spoon Plate
Large Fragment Spoon Plate

Large Fragment Spoon Plate

Rs 2,160  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Model Name/NumberSP05.SPSS
Size3.5mm,4.5mm & 6.5mm (Screw)
BrandSHARMA
MaterialStainless Steel 316l / 316lvm / Titanium
No. Of Hole4,5,6,7
Distance Between Hole20.0mm
Profile33.0mm x 18.5mm x 3.0mm
Suitable ForPilon Fracture,Distal Tibia Fracture & Proximal Humerus Fracture
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

Additional Information:

  • Item Code: SP05.SPSS
  • Production Capacity: 1000
  • Delivery Time: 15 DAYS
  • Packaging Details: POLY PACK

View Complete details

get quoterequest a call back
  • Cobra Plate
  • Cobra Plate
Cobra Plate

Cobra Plate

Rs 1,800  / PieceGet Best Price
MaterialStainless Steel 316l / 316lvm / Titanium
Size4.5mm & 6.5mm(Screw)
BrandSharma
No. Of Hole2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18
Distance Between Hole16.0mm
Profile37.0mm/16.0mmx5.0mm
Suitable ForArthrodesis Of The Hip Fracture
Proximal ScrewCancellous Screw (6.5mm)
  • Suitable For : Arthrodesis Of The Hip Fracture
  • Screw : 4.5mm & 6.5mm
  • Profile : 37.0mm/16.0mmx5.0mm
  • Distance Between Hole : 16.0mm
  • Material : Stainless Steel 316l / 316lvm / Titanium
  • Holes : 2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18
  • Proximal Screw : Cancellous Screw 6.5mm
  • Screw Length : 25.0mm To 110.0mm (diff. 5.0mm)
  • Distal Screw : Cortical Screw 4.5mm
  • Screw Length : 10.0mm To 54.0mm (diff. 2.0mm)

View Complete details

get quoterequest a call back
Left And Right Distal Tibia Anatomical Plate

Left And Right Distal Tibia Anatomical Plate

Rs 3,600  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Model Name/NumberSP05.DTAPLSS
BrandSHARMA
Holes4,5,6,7,8,9,10,11,12,13,14,15,16,17,18
MaterialStainless Steel 316l / 316lvm / Titanium
Suitable ForOsteotomy Of Distal Tibia Fracture
Country of OriginMade in India
Proximal ScrewCortical Screw 4.5mm
Distal ScrewCancellous Screw 6.5mm
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

Additional Information:

  • Item Code: SP05.DTAPLSS
  • Production Capacity: 1000
  • Delivery Time: 15 DAYS
  • Packaging Details: POLY PACK

View Complete details

get quoterequest a call back
  • Anatomical Distal Femur Plate
  • Anatomical Distal Femur Plate
Anatomical Distal Femur Plate

Anatomical Distal Femur Plate

Rs 3,816  / PieceGet Best Price
Model Name/NumberSP05.DTAPRSS
Size6.5mm & 4.5mm(Screw)
MaterialStainless Steel 316l / 316lvm / Titanium
BrandSHARMA
No. Of Hole4,5,6,7,8,9,10,11,12,13,14,15,16,17,18
Distance Between Hole18.0mm
Profile25.0mm / 13.5mm x 4.0mm
Suitable ForOsteotomy of Distal Tibia Fracture
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

View Complete details

get quoterequest a call back
  • Calcaneum Plate
  • Calcaneum Plate
  • Calcaneum Plate
  • Calcaneum Plate
Calcaneum Plate

Calcaneum Plate

Rs 1,440  / PieceGet Best Price
Size3.5mm & 4.5mm(Screw)
MaterialStainless Steel 316l / 316lvm / Titanium
BrandSharma
Distance Between Hole10.0mm
Profile42.5mm/7.5mmx2.0mm
Suitable ForCalcanium Fracture
Proximal ScrewCortical Screw (3.5mm)
Distal ScrewCortical Screw (4.5mm)
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

View Complete details

get quoterequest a call back
  • Narrow Dynamic Compression Plate
  • Narrow Dynamic Compression Plate
  • Narrow Dynamic Compression Plate
Narrow Dynamic Compression Plate

Narrow Dynamic Compression Plate

Rs 500  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Size4.5mm (Screw) and 6.5mm (Screw)
BrandSHARMA
MaterialStainless steel 316l / 316lvm / Titanium
ColorBlack
Screw Length10.0mm to 54.0mm (diff. 2.0mm), 25.0mm to 110.0mm (diff. 5.0mm)
Shaft PartCortical screw (4.5mm) , cancellous screw (6.5mm)
Profile16.0mm x 4.0mm
No. Of Hole2,3,4,5,6,7,8,9,10,11,12,13,14,15,16
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 15 DAYS
  • Packaging Details: POLY PACK

View Complete details

get quoterequest a call back
  • Narrow Low Contact Dynamic Compression Plate
  • Narrow Low Contact Dynamic Compression Plate
Narrow Low Contact Dynamic Compression Plate

Narrow Low Contact Dynamic Compression Plate

Rs 1,908  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Size4.5mm, 6.5mm (Screw)
BrandSHARMA
MaterialStainless Steel 316l / 316lvm / Titanium
Screw Length10.0mm To 54.0mm (diff. 2.0mm),25.0mm To 110.0mm (diff. 5.0mm)
Shaft PartCortical Screw (4.5mm),Cancellous Screw (6.5mm)
Profile16.0mm X 4.5mm
No. Of Hole5,6,7,8,9,10,11,12,13,16,17,18
Distance Between Hole18.0mm
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 15 DAYS
  • Packaging Details: POLY PACK

View Complete details

get quoterequest a call back
  • Broad Dynamic Compression Plate
  • Broad Dynamic Compression Plate
Broad Dynamic Compression Plate

Broad Dynamic Compression Plate

Rs 1,728  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Model Name/NumberSP05.DCPBSS
Size5.0mm X 6.5 mm (Screw)
BrandSHARMA
MaterialStainless Steel 316l / 316lvm / Titanium
Screw Length10.0mm To 54.0mm (diff. 2.0mm),25.0mm To 110.0mm (diff. 5.0mm)
Shaft PartCortical Screw (4.5mm),Cancellous Screw (6.5mm)
Profile16.5mm X5.0mm
No. Of Hole2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

Additional Information:

  • Item Code: SP05.DCPBSS
  • Production Capacity: 1000
  • Delivery Time: 15 DAYS
  • Packaging Details: POLY PACK

View Complete details

get quoterequest a call back
  • Broad Low Contact Dynamic Compression Plate
  • Broad Low Contact Dynamic Compression Plate
Broad Low Contact Dynamic Compression Plate

Broad Low Contact Dynamic Compression Plate

Rs 775  / PieceGet Best Price

Minimum Order Quantity: 50 Piece

Thickness4.5
TypeLarge Fragment
Size4.5mm & 6.5mm (Screw)
MaterialStainless Steel 316l / 316lvm / Titanium
BrandSharma
Screw Length10.0mm To 54.0mm (diff. 2.0mm), 20.0mm To 120.0mm (diff. 5.0mm)
Shaft PartCortical Screw (4.5mm), Cancellous Screw (6.5mm)
No. Of Hole4,5,6,7,8,9,10,11,12,13,16,17,18
Indications:

Broad LC-DCP
 4.5. These plates are indicated for fixation of various long bones, such as the humerus, femur and tibia. These are also used in fixation of peri-prosthetic fractures, osteopenic bone and fixation of non-unions and malunions in adult patients. ... The end holes can be used for cancellous bone screws.

Additional Information:

  • Item Code: SO19.4.5LCDCP
  • Production Capacity: 2000
  • Delivery Time: 15 DAYS
  • Packaging Details: ONE PIECE POLY PACK

View Complete details

get quoterequest a call back
  • R/H, D.C H L/B Or S/B DHS Plate
  • R/H, D.C H L/B Or S/B DHS Plate
R/H, D.C H L/B Or S/B DHS Plate

R/H, D.C H L/B Or S/B DHS Plate

Rs 1,728  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Model Name/NumberSP05.DHSPSBDCHSS
MaterialStainless Steel 316l / 316lvm / Titanium
BrandSHARMA
Size12. 5mm X 4. 5mm(Screw)
Angle125 Degree,130 Degree,135 Degree,140 Degree
No. Of Hole2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18
Distance Between Hole16. 0mm
Profile19. 0mm X 6. 0mm
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

Additional Information:

  • Item Code: SP05.DHSPSBDCHSS
  • Production Capacity: 1000
  • Delivery Time: 15 DAYS
  • Packaging Details: POLY PACK

View Complete details

get quoterequest a call back
  • 95 Degree R/H And D.C/H DCS Plate
  • 95 Degree R/H And D.C/H DCS Plate
95 Degree R/H And D.C/H DCS Plate

95 Degree R/H And D.C/H DCS Plate

Rs 1,728  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Model Name/NumberSP05.DCSPDCHSS
Size12. 5mm X 4. 5mm X 4.5mm (Screw)
MaterialStainless Steel 316l / 316lvm / Titanium
BrandSHARMA
CAT NumberSP05.DCSPDCHSS
Number Of Holes2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18
Distance Between Hole16.0mm
Profile16.0mm X 6. 0mm
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

Additional Information:

  • Item Code: SP05.DCSPDCHSS
  • Production Capacity: 1000
  • Delivery Time: 15 DAYS
  • Packaging Details: POLY PACK

View Complete details

get quoterequest a call back
  • DC Hole Angled Blade Plate
  • DC Hole Angled Blade Plate
DC Hole Angled Blade Plate

DC Hole Angled Blade Plate

Rs 2,880  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Model Name/NumberSP05.ABPDCHSS
Size4.5mm (Screw)
MaterialStainless Steel 316l / 316lvm / Titanium
BrandSHARMA
No. Of Hole4,5,6,7,8,9,10,11,12,13,14,15,16,17,18
Distance Between Hole16.0mm
Profile16.0mmx6.0mm
Suitable ForFemur Neck & Trochantric Fracture
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

Additional Information:

  • Item Code: SP05.ABPDCHSS
  • Production Capacity: 1000
  • Delivery Time: 15 DAYS
  • Packaging Details: POLY PACK

View Complete details

get quoterequest a call back
  • Semi Tubular Plate
  • Semi Tubular Plate
Semi Tubular Plate

Semi Tubular Plate

Rs 220  / PieceGet Best Price

Minimum Order Quantity: 50 Piece

ThicknessSTD
Size4.5mm(Screw)
MaterialStainless Steel 316l / 316lvm / Titanium
Number Of Holes3,4,5,6,7,8,9,10,11,12,13,14
Distance Between Hole16.0mm
Profile13.0mm X 1.5mm
Suitable ForFracture Of Radius / Ulna Fibula Use As A Tension Bone Plate On Radius / Ulna, Humerus & Tibia Plate
BRANDSharma
Indications:

Semi
-Tubular Plate 4.5. These plates are primarily indicated for areas of low stress such as forearm-radius, and are also recommended for the fractures of fibula. 

Additional Information:

  • Item Code: SO19.STP
  • Production Capacity: 2000
  • Delivery Time: 15 DAYS
  • Packaging Details: ONE PIECE POLY PACK

View Complete details

get quoterequest a call back
  • Lateral Tibia Head Buttress Plate
  • Lateral Tibia Head Buttress Plate
Lateral Tibia Head Buttress Plate

Lateral Tibia Head Buttress Plate

Rs 2,556  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Model Name/NumberSP05.LTHBPLSS
Size4.5mm & 6.5mm (Screw)
MaterialStainless Steel 316l / 316lvm / Titanium
BrandSharma
No. Of Hole4,5,6,7,8,9,10,11,12,13,14,15,16
Distance Between Hole16.0mm
Profile25.0mm/14.0mmx45.0mm
Suitable ForProximal Tibia Fracture
  • bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.


Additional Information:

  • Item Code: SP05.LTHBPLSS
  • Production Capacity: 1000
  • Delivery Time: 15 DAYS
  • Packaging Details: POLY PACK

View Complete details

get quoterequest a call back
  • 95 Degree Condylar Plate With Blade
  • 95 Degree Condylar Plate With Blade
95 Degree Condylar Plate With Blade

95 Degree Condylar Plate With Blade

Rs 2,880  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Model Name/NumberSP05.CPWBSS
Size4.5mm & 6.5mm(Screw)
MaterialStainless Steel 316l / 316lvm / Titanium
No. Of Hole4,5,6,7,8,9,10,11,12,13,14,15,16,17,18
Distance Between Hole16.0mm
Profile16.0mmx6.0mm
Suitable ForSupracondylar & Distal Femur Fracture
MakeSharma
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

Additional Information:

  • Item Code: SP05.CPWBSS
  • Production Capacity: 1000
  • Delivery Time: 15 DAYS
  • Packaging Details: POLY PACK

View Complete details

get quoterequest a call back
T - Plate

T - Plate

Rs 504  / PieceGet Best Price

Minimum Order Quantity: 50 Piece

Thickness4.5mm
Size6.5mm & 4.5mm(Screw)
MaterialStainless Steel 316l / 316lvm / Titanium
No. Of Hole4,5,6,7,8,9,10,11,12
Distance Between Hole16.0mm
Profile36.0mm/16.0mmx2.0mm
Suitable ForProximal Tibia Fracture
MakeSharma
Indicataions:

It is also used in the distal tibia, proximal tibia and proximal humerus fractures. 

Additional Information:

  • Item Code: SO19.4.5TP
  • Production Capacity: 2000
  • Delivery Time: 15 DAYS
  • Packaging Details: ONE PIECE POLY PACK

View Complete details

get quoterequest a call back
  • T - Buttress Plate
  • T - Buttress Plate
T - Buttress Plate

T - Buttress Plate

Rs 504  / PieceGet Best Price

Minimum Order Quantity: 50 Piece

Thickness4.5mm
Size6.5mm & 4.5mm(Screw)
MaterialStainless Steel 316l / 316lvm / Titanium
BrandSharma
No. Of Hole4,5,6,7,8,9,10,11,12
Distance Between Hole16.0mm
Profile36.0mm/16.0mmx2.0mm
Suitable ForProximal Tibia Fracture
Indications:

It is also used in the distal tibia,proximal tibia and proximal humerus fractures. 

Additional Information:

  • Item Code: SO19.4.5TBP
  • Production Capacity: 2000
  • Delivery Time: 15 DAYS
  • Packaging Details: ONE PIECE POLY PACK

View Complete details

get quoterequest a call back
  • L - Plate
  • L - Plate
L - Plate

L - Plate

Rs 504  / PieceGet Best Price

Minimum Order Quantity: 50 Piece

Size6.5mm & 4.5mm(Screw)
Thickness4.5mm
MaterialStainless Steel 316l / 316lvm / Titanium
BrandSharma
Suitable ForProximal Tibia Fracture
No. Of Hole3,4,5,6,7,8,9,10,11,12
Distance Between Hole16.0mm
Profile36.0mm/16.0mmx2.0mm
Indicataion:

4.5mm “L” Buttress Plate is indicated to be used as buttress for tibial and humeral head fractures

Additional Information:

  • Item Code: SO19.LP
  • Production Capacity: 2000
  • Delivery Time: 15 DAYS
  • Packaging Details: ONE PIECE POLY PACK

View Complete details

get quoterequest a call back
  • L Buttress Plate
  • L Buttress Plate
L Buttress Plate

L Buttress Plate

Rs 504  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Model Name/NumberSP05.LBPLSS
Size6.5mm & 4.5mm(Screw)
MaterialStainless Steel 316l / 316lvm / Titanium
ShapeL
BrandSharma
Usage/ApplicationProximal Tibia Fracture
Suitable ForProximal Tibia Fracture
CAT NumberSP05.LBPLSS
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 15 DAYS
  • Packaging Details: POLY PACKC

View Complete details

get quoterequest a call back
  • Femoral Condylar Buttress Plate
  • Femoral Condylar Buttress Plate
Femoral Condylar Buttress Plate

Femoral Condylar Buttress Plate

Rs 2,880  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Model Name/NumberSP05.DTAPLSS
Size6.5mm & 4.5mm(Screw)
MaterialStainless Steel 316l / 316lvm / Titanium
Number Of Holes4,5,6,7,8,9,10,11,12,13,14,15,16
BrandSHARMA
CAT NumberSP05.DTAPLSS
Screw Length10.0mm To 54.0mm (diff. 2.0mm), 25.0mm To 110.0mm (diff. 5.0mm)
Distance Between Hole16.0mm
bone plate is a thin metal implant used to immobilize bone segments. The plate is affixed with screws to properly align the bone and aid in the healing process. In spine surgery, a bone plate may be used to help stabilize the fused area and prevent dislodgement of the bone graft.

Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 15 DAYS
  • Packaging Details: POLY PACK

View Complete details

get quoterequest a call back
  • Clover Leaf Plate
  • Clover Leaf Plate
Clover Leaf Plate

Clover Leaf Plate

Rs 1,200  / PieceGet Best Price
Size4.0mm and 4.5mm (Screw)
ShapeClover Leaf shape
MaterialStainless Steel 316l / 316lvm / Titanium
Screw Length4.0mm*10.0mm To 50.0mm (diff. 5.0mm), 4.5mm10.0mm To 36.0mm (diff. 2.0mm)
ColorBlack
PackagingPOLY PACK
No. Of Hole4,5,6,7,8,9,10,11,12
Distance Between Hole16.0mm
Cloverleaf plate. Cloverleaf is a system used in fractures of the distal tibia and proximal humerus. These plates are fixed by both cortical and cancellous screws.

View Complete details

get quoterequest a call back

EXPLORE MORE CATEGORIES